Current - Output (Max)
|
Current - Continuous RMS
|
Current Limit (Standard)
|
Fault Reporting
|
Control Features
|
Sleep Mode
|
IC Package
|
Breakdown Voltage
|
Topology
|
Product Type
|
Over-Current Response
|
Auto-Restart & Overvoltage Response
|
Over-Temperature Response
|
Protection Features
|
Temperature - Operating (Min)
|
Temperature - Operating (Max)
|
MSL Rating
|
RDK Available
|
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Data Sheet
View Data Sheet
|
Current - Output (Max)
1A
|
Current - Continuous RMS
0.22 A
|
Current Limit (Standard)
0.9A
|
Fault Reporting
FAULT Bus
|
Control Features
Remote Fault Reset, Self-Biased Drivers
|
Sleep Mode
<12 mW
|
IC Package
InSOP-24C
|
Breakdown Voltage
600 V
|
Topology
LLC Half Bridge
|
Product Type
IC
|
Over-Current Response
Cycle-by-Cycle, Latch Off
|
Auto-Restart & Overvoltage Response
Hysteretic
|
Over-Temperature Response
Hysteretic, Latch Off
|
Protection Features
Output Undervoltage, Overtemperature, Input Overvoltage, Input Undervoltage, Output Overvoltage, Thermal Overload, System Temperature
|
Temperature - Operating (Min)
-40 °C
|
Temperature - Operating (Max)
150 °C
|
MSL Rating
3
|
RDK Available
|
|
||
Data Sheet
View Data Sheet
|
Current - Output (Max)
2A
|
Current - Continuous RMS
0.50 A
|
Current Limit (Standard)
1.5A
|
Fault Reporting
FAULT Bus
|
Control Features
Remote Fault Reset, Self-Biased Drivers
|
Sleep Mode
<12 mW
|
IC Package
InSOP-24C
|
Breakdown Voltage
600 V
|
Topology
LLC Half Bridge
|
Product Type
IC
|
Over-Current Response
Cycle-by-Cycle, Latch Off
|
Auto-Restart & Overvoltage Response
Hysteretic
|
Over-Temperature Response
Hysteretic, Latch Off
|
Protection Features
Output Undervoltage, Overtemperature, Input Overvoltage, Input Undervoltage, Output Overvoltage, Thermal Overload, System Temperature
|
Temperature - Operating (Min)
-40 °C
|
Temperature - Operating (Max)
150 °C
|
MSL Rating
3
|
RDK Available
|
|
||
Data Sheet
View Data Sheet
|
Current - Output (Max)
3A
|
Current - Continuous RMS
0.75 A
|
Current Limit (Standard)
2.5A
|
Fault Reporting
FAULT Bus
|
Control Features
Remote Fault Reset, Self-Biased Drivers
|
Sleep Mode
<12 mW
|
IC Package
InSOP-24C
|
Breakdown Voltage
600 V
|
Topology
LLC Half Bridge
|
Product Type
IC
|
Over-Current Response
Cycle-by-Cycle, Latch Off
|
Auto-Restart & Overvoltage Response
Hysteretic
|
Over-Temperature Response
Hysteretic, Latch Off
|
Protection Features
Output Undervoltage, Overtemperature, Input Overvoltage, Input Undervoltage, Output Overvoltage, Thermal Overload, System Temperature
|
Temperature - Operating (Min)
-40 °C
|
Temperature - Operating (Max)
150 °C
|
MSL Rating
3
|
RDK Available
|
|
||
Data Sheet
View Data Sheet
|
Current - Output (Max)
6A
|
Current - Continuous RMS
1.00 A
|
Current Limit (Standard)
3.3A
|
Fault Reporting
FAULT Bus
|
Control Features
Remote Fault Reset, Self-Biased Drivers
|
Sleep Mode
<12 mW
|
IC Package
InSOP-24C
|
Breakdown Voltage
600 V
|
Topology
LLC Half Bridge
|
Product Type
IC
|
Over-Current Response
Cycle-by-Cycle, Latch Off
|
Auto-Restart & Overvoltage Response
Hysteretic
|
Over-Temperature Response
Hysteretic, Latch Off
|
Protection Features
Output Undervoltage, Overtemperature, Input Overvoltage, Input Undervoltage, Output Overvoltage, Thermal Overload, System Temperature
|
Temperature - Operating (Min)
-40 °C
|
Temperature - Operating (Max)
150 °C
|
MSL Rating
3
|
RDK Available
|
|
||
Data Sheet
View Data Sheet
|
Current - Output (Max)
12A
|
Current - Continuous RMS
1.33 A
|
Current Limit (Standard)
4.4A
|
Fault Reporting
FAULT Bus
|
Control Features
Remote Fault Reset, Self-Biased Drivers
|
Sleep Mode
<12 mW
|
IC Package
InSOP-24C
|
Breakdown Voltage
600 V
|
Topology
LLC Half Bridge
|
Product Type
IC
|
Over-Current Response
Cycle-by-Cycle, Latch Off
|
Auto-Restart & Overvoltage Response
Hysteretic
|
Over-Temperature Response
Hysteretic, Latch Off
|
Protection Features
Output Undervoltage, Overtemperature, Input Overvoltage, Input Undervoltage, Output Overvoltage, Thermal Overload, System Temperature
|
Temperature - Operating (Min)
-40 °C
|
Temperature - Operating (Max)
150 °C
|
MSL Rating
3
|
RDK Available
|
|
||
Data Sheet
View Data Sheet
|
Current - Output (Max)
1A
|
Current - Continuous RMS
0.22 A
|
Current Limit (Standard)
0.9A
|
Fault Reporting
FAULT Bus
|
Control Features
Phase Current Info, Remote Fault Reset, Self-Biased Drivers
|
Sleep Mode
<12 mW
|
IC Package
InSOP-24C
|
Breakdown Voltage
600 V
|
Topology
LLC Half Bridge
|
Product Type
IC
|
Over-Current Response
Cycle-by-Cycle, Latch Off
|
Auto-Restart & Overvoltage Response
Hysteretic
|
Over-Temperature Response
Hysteretic, Latch Off
|
Protection Features
Output Undervoltage, Overtemperature, Input Overvoltage, Input Undervoltage, Output Overvoltage, Thermal Overload, System Temperature
|
Temperature - Operating (Min)
-40 °C
|
Temperature - Operating (Max)
150 °C
|
MSL Rating
3
|
RDK Available
|
|
||
Data Sheet
View Data Sheet
|
Current - Output (Max)
2A
|
Current - Continuous RMS
0.50 A
|
Current Limit (Standard)
1.5A
|
Fault Reporting
FAULT Bus
|
Control Features
Phase Current Info, Remote Fault Reset, Self-Biased Drivers
|
Sleep Mode
<12 mW
|
IC Package
InSOP-24C
|
Breakdown Voltage
600 V
|
Topology
LLC Half Bridge
|
Product Type
IC
|
Over-Current Response
Cycle-by-Cycle, Latch Off
|
Auto-Restart & Overvoltage Response
Hysteretic
|
Over-Temperature Response
Hysteretic, Latch Off
|
Protection Features
Output Undervoltage, Overtemperature, Input Overvoltage, Input Undervoltage, Output Overvoltage, Thermal Overload, System Temperature
|
Temperature - Operating (Min)
-40 °C
|
Temperature - Operating (Max)
150 °C
|
MSL Rating
3
|
RDK Available
|
|
||
Data Sheet
View Data Sheet
|
Current - Output (Max)
3A
|
Current - Continuous RMS
0.75 A
|
Current Limit (Standard)
2.5A
|
Fault Reporting
FAULT Bus
|
Control Features
Phase Current Info, Remote Fault Reset, Self-Biased Drivers
|
Sleep Mode
<12 mW
|
IC Package
InSOP-24C
|
Breakdown Voltage
600 V
|
Topology
LLC Half Bridge
|
Product Type
IC
|
Over-Current Response
Cycle-by-Cycle, Latch Off
|
Auto-Restart & Overvoltage Response
Hysteretic
|
Over-Temperature Response
Hysteretic, Latch Off
|
Protection Features
Output Undervoltage, Overtemperature, Input Overvoltage, Input Undervoltage, Output Overvoltage, Thermal Overload, System Temperature
|
Temperature - Operating (Min)
-40 °C
|
Temperature - Operating (Max)
150 °C
|
MSL Rating
3
|
RDK Available
|
|
||
Data Sheet
View Data Sheet
|
Current - Output (Max)
6A
|
Current - Continuous RMS
1.00 A
|
Current Limit (Standard)
3.3A
|
Fault Reporting
FAULT Bus
|
Control Features
Phase Current Info, Remote Fault Reset, Self-Biased Drivers
|
Sleep Mode
<12 mW
|
IC Package
InSOP-24C
|
Breakdown Voltage
600 V
|
Topology
LLC Half Bridge
|
Product Type
IC
|
Over-Current Response
Cycle-by-Cycle, Latch Off
|
Auto-Restart & Overvoltage Response
Hysteretic
|
Over-Temperature Response
Hysteretic, Latch Off
|
Protection Features
Output Undervoltage, Overtemperature, Input Overvoltage, Input Undervoltage, Output Overvoltage, Thermal Overload, System Temperature
|
Temperature - Operating (Min)
-40 °C
|
Temperature - Operating (Max)
150 °C
|
MSL Rating
3
|
RDK Available
|
|
||
Data Sheet
View Data Sheet
|
Current - Output (Max)
12A
|
Current - Continuous RMS
1.33 A
|
Current Limit (Standard)
4.4A
|
Fault Reporting
FAULT Bus
|
Control Features
Phase Current Info, Remote Fault Reset, Self-Biased Drivers
|
Sleep Mode
<12 mW
|
IC Package
InSOP-24C
|
Breakdown Voltage
600 V
|
Topology
LLC Half Bridge
|
Product Type
IC
|
Over-Current Response
Cycle-by-Cycle, Latch Off
|
Auto-Restart & Overvoltage Response
Hysteretic
|
Over-Temperature Response
Hysteretic, Latch Off
|
Protection Features
Output Undervoltage, Overtemperature, Input Overvoltage, Input Undervoltage, Output Overvoltage, Thermal Overload, System Temperature
|
Temperature - Operating (Min)
-40 °C
|
Temperature - Operating (Max)
150 °C
|
MSL Rating
3
|
RDK Available
|
|
||
Data Sheet
View Data Sheet
|
Current - Output (Max)
1A
|
Current - Continuous RMS
0.22 A
|
Current Limit (Standard)
0.9A
|
Fault Reporting
Error Flag (EF)
|
Control Features
Remote Fault Reset, Self-Biased Drivers
|
Sleep Mode
<12 mW
|
IC Package
InSOP-24C
|
Breakdown Voltage
600 V
|
Topology
LLC Half Bridge
|
Product Type
IC
|
Over-Current Response
Cycle-by-Cycle, Latch Off
|
Auto-Restart & Overvoltage Response
Hysteretic
|
Over-Temperature Response
Hysteretic, Latch Off
|
Protection Features
Output Undervoltage, Overtemperature, Input Overvoltage, Input Undervoltage, Output Overvoltage, Thermal Overload, System Temperature
|
Temperature - Operating (Min)
-40 °C
|
Temperature - Operating (Max)
150 °C
|
MSL Rating
3
|
RDK Available
|
|
||
Data Sheet
View Data Sheet
|
Current - Output (Max)
2A
|
Current - Continuous RMS
0.50 A
|
Current Limit (Standard)
1.5A
|
Fault Reporting
Error Flag (EF)
|
Control Features
Remote Fault Reset, Self-Biased Drivers
|
Sleep Mode
<12 mW
|
IC Package
InSOP-24C
|
Breakdown Voltage
600 V
|
Topology
LLC Half Bridge
|
Product Type
IC
|
Over-Current Response
Cycle-by-Cycle, Latch Off
|
Auto-Restart & Overvoltage Response
Hysteretic
|
Over-Temperature Response
Hysteretic, Latch Off
|
Protection Features
Output Undervoltage, Overtemperature, Input Overvoltage, Input Undervoltage, Output Overvoltage, Thermal Overload, System Temperature
|
Temperature - Operating (Min)
-40 °C
|
Temperature - Operating (Max)
150 °C
|
MSL Rating
3
|
RDK Available
|
|
||
Data Sheet
View Data Sheet
|
Current - Output (Max)
3A
|
Current - Continuous RMS
0.75 A
|
Current Limit (Standard)
2.5A
|
Fault Reporting
Error Flag (EF)
|
Control Features
Remote Fault Reset, Self-Biased Drivers
|
Sleep Mode
<12 mW
|
IC Package
InSOP-24C
|
Breakdown Voltage
600 V
|
Topology
LLC Half Bridge
|
Product Type
IC
|
Over-Current Response
Cycle-by-Cycle, Latch Off
|
Auto-Restart & Overvoltage Response
Hysteretic
|
Over-Temperature Response
Hysteretic, Latch Off
|
Protection Features
Output Undervoltage, Overtemperature, Input Overvoltage, Input Undervoltage, Output Overvoltage, Thermal Overload, System Temperature
|
Temperature - Operating (Min)
-40 °C
|
Temperature - Operating (Max)
150 °C
|
MSL Rating
3
|
RDK Available
|
|
||
Data Sheet
View Data Sheet
|
Current - Output (Max)
6A
|
Current - Continuous RMS
1.00 A
|
Current Limit (Standard)
3.3A
|
Fault Reporting
Error Flag (EF)
|
Control Features
Remote Fault Reset, Self-Biased Drivers
|
Sleep Mode
<12 mW
|
IC Package
InSOP-24C
|
Breakdown Voltage
600 V
|
Topology
LLC Half Bridge
|
Product Type
IC
|
Over-Current Response
Cycle-by-Cycle, Latch Off
|
Auto-Restart & Overvoltage Response
Hysteretic
|
Over-Temperature Response
Hysteretic, Latch Off
|
Protection Features
Output Undervoltage, Overtemperature, Input Overvoltage, Input Undervoltage, Output Overvoltage, Thermal Overload, System Temperature
|
Temperature - Operating (Min)
-40 °C
|
Temperature - Operating (Max)
150 °C
|
MSL Rating
3
|
RDK Available
|
|
||
Data Sheet
View Data Sheet
|
Current - Output (Max)
12A
|
Current - Continuous RMS
1.33 A
|
Current Limit (Standard)
4.4A
|
Fault Reporting
Error Flag (EF)
|
Control Features
Remote Fault Reset, Self-Biased Drivers
|
Sleep Mode
<12 mW
|
IC Package
InSOP-24C
|
Breakdown Voltage
600 V
|
Topology
LLC Half Bridge
|
Product Type
IC
|
Over-Current Response
Cycle-by-Cycle, Latch Off
|
Auto-Restart & Overvoltage Response
Hysteretic
|
Over-Temperature Response
Hysteretic, Latch Off
|
Protection Features
Output Undervoltage, Overtemperature, Input Overvoltage, Input Undervoltage, Output Overvoltage, Thermal Overload, System Temperature
|
Temperature - Operating (Min)
-40 °C
|
Temperature - Operating (Max)
150 °C
|
MSL Rating
3
|
RDK Available
|
|
||
Data Sheet
View Data Sheet
|
Current - Output (Max)
1A
|
Current - Continuous RMS
0.22 A
|
Current Limit (Standard)
0.9A
|
Fault Reporting
Error Flag (EF)
|
Control Features
Phase Current Info, Remote Fault Reset, Self-Biased Drivers
|
Sleep Mode
<12 mW
|
IC Package
InSOP-24C
|
Breakdown Voltage
600 V
|
Topology
LLC Half Bridge
|
Product Type
IC
|
Over-Current Response
Cycle-by-Cycle, Latch Off
|
Auto-Restart & Overvoltage Response
Hysteretic
|
Over-Temperature Response
Hysteretic, Latch Off
|
Protection Features
Output Undervoltage, Overtemperature, Input Overvoltage, Input Undervoltage, Output Overvoltage, Thermal Overload, System Temperature
|
Temperature - Operating (Min)
-40 °C
|
Temperature - Operating (Max)
150 °C
|
MSL Rating
3
|
RDK Available
|
|
||
Data Sheet
View Data Sheet
|
Current - Output (Max)
2A
|
Current - Continuous RMS
0.50 A
|
Current Limit (Standard)
1.5A
|
Fault Reporting
Error Flag (EF)
|
Control Features
Phase Current Info, Remote Fault Reset, Self-Biased Drivers
|
Sleep Mode
<12 mW
|
IC Package
InSOP-24C
|
Breakdown Voltage
600 V
|
Topology
LLC Half Bridge
|
Product Type
IC
|
Over-Current Response
Cycle-by-Cycle, Latch Off
|
Auto-Restart & Overvoltage Response
Hysteretic
|
Over-Temperature Response
Hysteretic, Latch Off
|
Protection Features
Output Undervoltage, Overtemperature, Input Overvoltage, Input Undervoltage, Output Overvoltage, Thermal Overload, System Temperature
|
Temperature - Operating (Min)
-40 °C
|
Temperature - Operating (Max)
150 °C
|
MSL Rating
3
|
RDK Available
|
|
||
Data Sheet
View Data Sheet
|
Current - Output (Max)
3A
|
Current - Continuous RMS
0.75 A
|
Current Limit (Standard)
2.5A
|
Fault Reporting
Error Flag (EF)
|
Control Features
Phase Current Info, Remote Fault Reset, Self-Biased Drivers
|
Sleep Mode
<12 mW
|
IC Package
InSOP-24C
|
Breakdown Voltage
600 V
|
Topology
LLC Half Bridge
|
Product Type
IC
|
Over-Current Response
Cycle-by-Cycle, Latch Off
|
Auto-Restart & Overvoltage Response
Hysteretic
|
Over-Temperature Response
Hysteretic, Latch Off
|
Protection Features
Output Undervoltage, Overtemperature, Input Overvoltage, Input Undervoltage, Output Overvoltage, Thermal Overload, System Temperature
|
Temperature - Operating (Min)
-40 °C
|
Temperature - Operating (Max)
150 °C
|
MSL Rating
3
|
RDK Available
|
|
||
Data Sheet
View Data Sheet
|
Current - Output (Max)
6A
|
Current - Continuous RMS
1.00 A
|
Current Limit (Standard)
3.3A
|
Fault Reporting
Error Flag (EF)
|
Control Features
Phase Current Info, Remote Fault Reset, Self-Biased Drivers
|
Sleep Mode
<12 mW
|
IC Package
InSOP-24C
|
Breakdown Voltage
600 V
|
Topology
LLC Half Bridge
|
Product Type
IC
|
Over-Current Response
Cycle-by-Cycle, Latch Off
|
Auto-Restart & Overvoltage Response
Hysteretic
|
Over-Temperature Response
Hysteretic, Latch Off
|
Protection Features
Output Undervoltage, Overtemperature, Input Overvoltage, Input Undervoltage, Output Overvoltage, Thermal Overload, System Temperature
|
Temperature - Operating (Min)
-40 °C
|
Temperature - Operating (Max)
150 °C
|
MSL Rating
3
|
RDK Available
|
|
||
Data Sheet
View Data Sheet
|
Current - Output (Max)
12A
|
Current - Continuous RMS
1.33 A
|
Current Limit (Standard)
4.4A
|
Fault Reporting
Error Flag (EF)
|
Control Features
Phase Current Info, Remote Fault Reset, Self-Biased Drivers
|
Sleep Mode
<12 mW
|
IC Package
InSOP-24C
|
Breakdown Voltage
600 V
|
Topology
LLC Half Bridge
|
Product Type
IC
|
Over-Current Response
Cycle-by-Cycle, Latch Off
|
Auto-Restart & Overvoltage Response
Hysteretic
|
Over-Temperature Response
Hysteretic, Latch Off
|
Protection Features
Output Undervoltage, Overtemperature, Input Overvoltage, Input Undervoltage, Output Overvoltage, Thermal Overload, System Temperature
|
Temperature - Operating (Min)
-40 °C
|
Temperature - Operating (Max)
150 °C
|
MSL Rating
3
|
RDK Available
|
|
||
|
Current - Output (Max)
12A
|
Current - Continuous RMS
1.45 A
|
Current Limit (Standard)
4.4A
|
Fault Reporting
FAULT Bus
|
Control Features
Remote Fault Reset, Self-Biased Drivers
|
Sleep Mode
<12 mW
|
IC Package
InSOP-L38
|
Breakdown Voltage
600 V
|
Topology
LLC Half Bridge
|
Product Type
IC
|
Over-Current Response
Cycle-by-Cycle, Latch Off
|
Auto-Restart & Overvoltage Response
Hysteretic
|
Over-Temperature Response
Hysteretic, Latch Off
|
Protection Features
Output Undervoltage, Overtemperature, Input Overvoltage, Input Undervoltage, Output Overvoltage, Thermal Overload, System Temperature
|
Temperature - Operating (Min)
-40 °C
|
Temperature - Operating (Max)
150 °C
|
MSL Rating
3
|
RDK Available
|
|
||
|
Current - Output (Max)
22A
|
Current - Continuous RMS
2.20 A
|
Current Limit (Standard)
7.0A
|
Fault Reporting
FAULT Bus
|
Control Features
Remote Fault Reset, Self-Biased Drivers
|
Sleep Mode
<12 mW
|
IC Package
InSOP-L38
|
Breakdown Voltage
600 V
|
Topology
LLC Half Bridge
|
Product Type
IC
|
Over-Current Response
Cycle-by-Cycle, Latch Off
|
Auto-Restart & Overvoltage Response
Hysteretic
|
Over-Temperature Response
Hysteretic, Latch Off
|
Protection Features
Output Undervoltage, Overtemperature, Input Overvoltage, Input Undervoltage, Output Overvoltage, Thermal Overload, System Temperature
|
Temperature - Operating (Min)
-40 °C
|
Temperature - Operating (Max)
150 °C
|
MSL Rating
3
|
RDK Available
|
|
||
|
Current - Output (Max)
12A
|
Current - Continuous RMS
1.45 A
|
Current Limit (Standard)
4.4A
|
Fault Reporting
FAULT Bus
|
Control Features
Phase Current Info, Remote Fault Reset, Self-Biased Drivers
|
Sleep Mode
<12 mW
|
IC Package
InSOP-L38
|
Breakdown Voltage
600 V
|
Topology
LLC Half Bridge
|
Product Type
IC
|
Over-Current Response
Cycle-by-Cycle, Latch Off
|
Auto-Restart & Overvoltage Response
Hysteretic
|
Over-Temperature Response
Hysteretic, Latch Off
|
Protection Features
Output Undervoltage, Overtemperature, Input Overvoltage, Input Undervoltage, Output Overvoltage, Thermal Overload, System Temperature
|
Temperature - Operating (Min)
-40 °C
|
Temperature - Operating (Max)
150 °C
|
MSL Rating
3
|
RDK Available
|
|
||
|
Current - Output (Max)
22A
|
Current - Continuous RMS
2.20 A
|
Current Limit (Standard)
7.0A
|
Fault Reporting
FAULT Bus
|
Control Features
Phase Current Info, Remote Fault Reset, Self-Biased Drivers
|
Sleep Mode
<12 mW
|
IC Package
InSOP-L38
|
Breakdown Voltage
600 V
|
Topology
LLC Half Bridge
|
Product Type
IC
|
Over-Current Response
Cycle-by-Cycle, Latch Off
|
Auto-Restart & Overvoltage Response
Hysteretic
|
Over-Temperature Response
Hysteretic, Latch Off
|
Protection Features
Output Undervoltage, Overtemperature, Input Overvoltage, Input Undervoltage, Output Overvoltage, Thermal Overload, System Temperature
|
Temperature - Operating (Min)
-40 °C
|
Temperature - Operating (Max)
150 °C
|
MSL Rating
3
|
RDK Available
|
|
||
|
Current - Output (Max)
12A
|
Current - Continuous RMS
1.45 A
|
Current Limit (Standard)
4.4A
|
Fault Reporting
Error Flag (EF)
|
Control Features
Remote Fault Reset, Self-Biased Drivers
|
Sleep Mode
<12 mW
|
IC Package
InSOP-L38
|
Breakdown Voltage
600 V
|
Topology
LLC Half Bridge
|
Product Type
IC
|
Over-Current Response
Cycle-by-Cycle, Latch Off
|
Auto-Restart & Overvoltage Response
Hysteretic
|
Over-Temperature Response
Hysteretic, Latch Off
|
Protection Features
Output Undervoltage, Overtemperature, Input Overvoltage, Input Undervoltage, Output Overvoltage, Thermal Overload, System Temperature
|
Temperature - Operating (Min)
-40 °C
|
Temperature - Operating (Max)
150 °C
|
MSL Rating
3
|
RDK Available
|
|
||
|
Current - Output (Max)
22A
|
Current - Continuous RMS
2.20 A
|
Current Limit (Standard)
7.0A
|
Fault Reporting
Error Flag (EF)
|
Control Features
Remote Fault Reset, Self-Biased Drivers
|
Sleep Mode
<12 mW
|
IC Package
InSOP-L38
|
Breakdown Voltage
600 V
|
Topology
LLC Half Bridge
|
Product Type
IC
|
Over-Current Response
Cycle-by-Cycle, Latch Off
|
Auto-Restart & Overvoltage Response
Hysteretic
|
Over-Temperature Response
Hysteretic, Latch Off
|
Protection Features
Output Undervoltage, Overtemperature, Input Overvoltage, Input Undervoltage, Output Overvoltage, Thermal Overload, System Temperature
|
Temperature - Operating (Min)
-40 °C
|
Temperature - Operating (Max)
150 °C
|
MSL Rating
3
|
RDK Available
|
|
||
|
Current - Output (Max)
12A
|
Current - Continuous RMS
1.45 A
|
Current Limit (Standard)
4.4A
|
Fault Reporting
Error Flag (EF)
|
Control Features
Phase Current Info, Remote Fault Reset, Self-Biased Drivers
|
Sleep Mode
<12 mW
|
IC Package
InSOP-L38
|
Breakdown Voltage
600 V
|
Topology
LLC Half Bridge
|
Product Type
IC
|
Over-Current Response
Cycle-by-Cycle, Latch Off
|
Auto-Restart & Overvoltage Response
Hysteretic
|
Over-Temperature Response
Hysteretic, Latch Off
|
Protection Features
Output Undervoltage, Overtemperature, Input Overvoltage, Input Undervoltage, Output Overvoltage, Thermal Overload, System Temperature
|
Temperature - Operating (Min)
-40 °C
|
Temperature - Operating (Max)
150 °C
|
MSL Rating
3
|
RDK Available
|
|
||
|
Current - Output (Max)
22A
|
Current - Continuous RMS
2.20 A
|
Current Limit (Standard)
7.0A
|
Fault Reporting
Error Flag (EF)
|
Control Features
Phase Current Info, Remote Fault Reset, Self-Biased Drivers
|
Sleep Mode
<12 mW
|
IC Package
InSOP-L38
|
Breakdown Voltage
600 V
|
Topology
LLC Half Bridge
|
Product Type
IC
|
Over-Current Response
Cycle-by-Cycle, Latch Off
|
Auto-Restart & Overvoltage Response
Hysteretic
|
Over-Temperature Response
Hysteretic, Latch Off
|
Protection Features
Output Undervoltage, Overtemperature, Input Overvoltage, Input Undervoltage, Output Overvoltage, Thermal Overload, System Temperature
|
Temperature - Operating (Min)
-40 °C
|
Temperature - Operating (Max)
150 °C
|
MSL Rating
3
|
RDK Available
|
|
BridgeSwitch-2 expands available output to 1 horsepower (746 W), improves inverter efficiency to 99% and reduces sleep mode consumption to lower than 10mW.
The BridgeSwitch-2 family of integrated half-bridges dramatically simplifies the development and production of high-voltage inverter driven 1 or 3-phase PM or BLDC motor drives. It incorporates two high-voltage N-channel power FREDFETs with low and high-side drivers in a single small-outline package. The internal power FREDFETs offer ultra-soft and ultrafast diodes ideally suited for hard switched inverter drives. Both drivers are self-supplied eliminating the need for an external auxiliary power supply. BridgeSwitch-2 provides a unique instantaneous phase current output signal simplifying implementation of sensor-less control schemes. The low-profile, compact footprint surface mount package offers extended creepage distances and allows heat sinking of both power FREDFETs through the printed circuit board.
Start your single- or three-phase motor inverter design with MotorXpert Suite software.
BridgeSwitch-2 offers internal fault protection functions and external system level monitoring. Internal fault protection includes cycle-bycycle current limit for both FREDFETs and two level thermal overload protection. External system level monitoring includes DC bus sensing with four undervoltage levels and one overvoltage level as well as driving external sensors such as an NTC. The bi-directional bussed single wire status interface reports observed status changes. The new Sleep Mode reduces per device consumption to less than 4 mW from a rectified AC mains bus when using self-supplied operation.
© 2024 Power Integrations. All Rights Reserved